CHHVB - LITHIUM THIONYL CHLORIDE BATTERY

Product Identification

Product ID:LITHIUM THIONYL CHLORIDE BATTERY
MSDS Date:03/01/1994
FSC:6135
NIIN:01-324-2505
MSDS Number: CHHVB

Responsible Party
SAFT AMERICA INC ADVANCED BATTERY SYSTEMS DIVISION
313 CRESCENT STREET
VALDESE, NC 28690
US

Emergency Phone: 704-874-4111/MD 410-771-3200

Info Phone: 704-874-4111/CORP 912-247-2331

Cage: 7X634

Contractor
SAFT AMERICA INC ADVANCED BATTERY SYSTEMS DIVISION
VALDESE, NC 28690-9643 US

Telephone: 828-874-4111/912-245-2806

Cage: 7X634

Ingredients

THIONYL CHLORIDE

CAS: 7719-09-7

RTECS: XM5150000

OSHA PEL C 1 PPM

ACGIH TLV: C 1 PPM; 9596


LITHIUM METAL

CAS: 7439-93-2

RTECS: OJ5540000

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:IF CELL SEAL IS BROKEN, THE SUBSTANCE
AND VAPORS HAVE A CORROSIVE EFFECT ON THE SKIN AND MUCOUS
MEMBRANES.
Effects of Overexposure:BURNS AND IRRITATION TO RESPIRATORY SYSTEM.
Medical Cond Aggravated by Exposure:ASTHMA AND OTHER RESPIRATORY
DISEASES.

First Aid

First Aid:EYES: FLUSH IMMEDIATELY WITH WTAER FOR 15 MIN. SKIN: WASH
WITH PLENTY OF WATER AND TAKE OFF CONTAMINATED CLOTHES.
INHALATION: REMOVE FROM EXPOSURE, SEEK MEDICAL ATTENTION.

Fire Fighting

Extinguishing Media:USE WATER OR CARBON DIOXIDE ON BURNING LITHIUM
THIONYL CHLORIDE CELLS OR BATTERIES.
Fire Fighting Procedures:USE SELF-CONTAINED BREATHING APPARATUS. NOTE:
USE A CLASS D FIRE EXTINGUISHING AGENT ONLY ON A RAW LITHIUM FIRE.
Unusual Fire/Explosion Hazard:GENERATION OF CHLORINE, SULFUR DIOXIDE,
DISULFUR DICHLORIDE DURING THERMAL DECOMPOSITION.

Accidental Release

Spill Release Procedures:COVER WITH SODIUM CARBONATE OR 1:1 MIXTURE OF
SODA ASH AND SLAKED LIME.

Handling

Handling and Storage Precautions:DO NOT RECHARGE, SHORT CIRCUIT,
PUNCTURE OR MUTILATE. DO NOT EXPOSE TO TEMPERATURES IN EXCESS OF
85C (185F). DO NOT EXPOSE TO WATER OR CORROSIVES.
Other Precautions:IF CONTAMINATION WITH MOISTURE OCCURS, PRODUCT WILL
RELAESE GAS CAUSING A PRESSURE BUILD-UP WHICH COULD RESULT IN DRUM
RUPTURE.

Exposure Controls

Eye Protection:SAFETY GLASSES.
Work Hygienic Practices:KEEP ONLY IN THE ORIGINAL CONTAINER. HANDLE AND
OPEN CONTAINER WITH CARE. ENSURE EFFECTIVE VENTILATION.
Supplemental Safety and Health

Chemical Properties

HCC:N1
Melt/Freeze Pt:M.P/F.P Text:374F,190C
Decomp Temp:Decomp Text:284F,140C
Spec Gravity:>1
Solubility in Water:NOT SOLUBLE

Stability

Stability Indicator/Materials to Avoid:YES
WATER ALKALIS.
Stability Condition to Avoid:CELLS ARE NON REACTING PROVIDED THE CELL
SEAL REMAINS INTACT. THERMAL DECOMPOSITION BEGINS AT 140C.
Hazardous Decomposition Products:HYDROGEN, SULFUR DIOXIDE, SULFUR
DICHLORIDE, DISULFUR DICHLORIDE, CHLORINE.

Disposal

Waste Disposal Methods:PRODUCT DECOMPOSED BY WATER MUST BE NEUTRALIZED,
MAY BE ADDED TO WASTE WATER IN SUFFICIENLY DILUTED FORM.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.